| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | YUJIE |
| Model Number : | UM4000-SR55-AU |
| Certification : | ISO9001 |
| Price : | Negotiable |
| Payment Terms : | T/T, Western Union, MoneyGram |
| Supply Ability : | 5000 Piece/Pieces per Month |
| Delivery Time : | 3~30 working days |
High Accuracy Ultrasonic Sensor Level Measurement With PBT OR FRP l Housing
Highlights
| Ultrasonic sensor | UM4000-SR55-AU | |||
| Technical data | ||||
| General Specifications | ||||
| Sensing distance | 280…4000mm(200---3000mm) | |||
| Adjustment range | 280…4000mm | |||
| Unusable area | 0…280mm | |||
| Standard target plate | 100mm×100mm | |||
| Transducer frequency About | 75 kHz | |||
| Response delay About | 125ms | |||
| Indicators/Operating means | ||||
| LED yellow | solid: NO LED flash: | |||
| LED red | flashing: | |||
| Electrical specifications |
| |||
| Operating voltage UB | 10…30VDC ripple10%ss | |||
| No-load supply current | ≤30mA | |||
| Output | ||||
| Output type | 1 analogue output 0---5V | |||
| Resolution | ||||
| Deviation of the characteristic curve | ±1% of full-scale value | |||
| Repeat accuracy | ±0.1% of full-scale value | |||
| Load impedance | >1k Ohm | |||
| Maximum switching current | mA | |||
| Temperature influence | ±1.5% of full-scale value | |||
| Ambient conditions | ||||
| Ambient temperature | -25…70℃ | |||
| Storage temperature | -40…85℃ | |||
| Mechanical specifications | ||||
| Protection grade | IP68 | |||
| Connection | PVC cable,4-PIN | |||
| Material | ||||
| Housing | PBT OR FRP | |||
| Transducer | epoxy resin/hollow glass sphere mixture; Polyurethane foam | 1 BN=BROWN 2 GN=GREEN 3 BU=BLUE 4 BK=BLACK | ||
| Weight | 150g | |||
| Compliance with standards and Directives | ||||
| Standard conformity | EN 60947-5-2:2007 | |||
Adjusting the evaluation limits The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply voltage -UB or +UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. indicate whether the sensor has recognised the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught with -UB, A2 with +UB. Two different output functions can be set: 1. Analogue value increases with rising distance to object (rising ramp) 2. Analogue value falls with rising distance to object (falling ramp) Evaluation limits may only be specified within the first 5 minutes after Power on. To modify the evaluation limits later, the user may specify the desired values only after a new Power On. TEACH-IN rising ramp (A2 > A1) - Position object at lower evaluation limit - TEACH-IN lower limit A1 with - UB - Position object at upper evaluation limit - TEACH-IN upper limit A2 with + UB TEACH-IN falling ramp (A1 > A2): - Position object at lower evaluation limit - TEACH-IN lower limit A2 with + UB - Position object at upper evaluation limit - TEACH-IN upper limit A1 with - UB Default setting A1: unusable area A2: nominal sensing range Mode of operation: rising ramp LED Displays (SMP80 series no led)
|
|