| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | YUJIE |
| Model Number : | UM6000-30GM-AU-V1 |
| Certification : | ISO9001 |
| Price : | Negotiable |
| Payment Terms : | T/T, Western Union, MoneyGram |
| Supply Ability : | 5000 Piece/Pieces per Month |
| Delivery Time : | 3~30 working days |
High Accuracy Ultrasonic Level Sensor Measurement Range 300…6000mm With Brass Nickel-plated Housing
Highlights
| Ultrasonic sensor | UM6000-30GM-AU-V1 | |||
| Technical data |
| |||
| General Specifications | ||||
| Sensing distance | 300…6000mm | |||
| Adjustment range | 300…6000mm | |||
| Unusable area | 0…300mm | |||
| Standard target plate | 100mm×100mm | |||
| Transducer frequency About | 65 kHz | |||
| Response delay About | 125ms | |||
| Indicators/Operating means | ||||
| LED yellow | solid: object in evaluation range flash: program function | |||
| LED red | flashing: program function | |||
| Electrical specifications |
| |||
| Operating voltage UB | 10…30VDC ripple10%ss | |||
| No-load supply current | ≤30mA | |||
| Output | ||||
| Output type | 1 analogue output 0---10V | |||
| Resolution | ||||
| Deviation of the characteristic curve | ±1% of full-scale value | |||
| Repeat accuracy | ±0.1% of full-scale value | |||
| Load impedance | >1k Ohm | |||
| Maximum switching current | ||||
| Temperature influence | ±1.5% of full-scale value | |||
| Ambient conditions | ||||
| Ambient temperature | -25…70℃ | |||
| Storage temperature | -40…85℃ | |||
| Mechanical specifications |
| |||
| Protection grade | IP67 | |||
| Connection | Connector M12,4-PIN | |||
| Material | ||||
| Housing | Brass nickel-plated | |||
| Transducer | epoxy resin/hollow glass sphere mixture; Polyurethane foam | 1 BN=BROWN 2 WH=WHITE 3 BU=BLUE 4 BK=BLACK | ||
| Weight | 360g | |||
| Compliance with standards and Directives | ||||
| Standard conformity | EN 60947-5-2:2007 | |||
Adjusting the evaluation limits The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply voltage -UB or +UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs indicate whether the sensor has recognised the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught with -UB, A2 with +UB. Two different output functions can be set: 1. Analogue value increases with rising distance to object (rising ramp) 2. Analogue value falls with rising distance to object (falling ramp) Evaluation limits may only be specified within the first 5 minutes after
the user may specify the desired values only after a new Power On. TEACH-IN rising ramp (A2 > A1) - Position object at lower evaluation limit - TEACH-IN lower limit A1 with - UB - Position object at upper evaluation limit - TEACH-IN upper limit A2 with + UB TEACH-IN falling ramp (A1 > A2): - Position object at lower evaluation limit - TEACH-IN lower limit A2 with + UB - Position object at upper evaluation limit - TEACH-IN upper limit A1 with - UB Default setting A1: unusable area A2: nominal sensing range Mode of operation: rising ramp LED Displays
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|